Disel generator
Aksa AD 710

Model : AD 710
Product : HYUNDAI
CONTROL SYSTEM : DSE 7320
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AD 710
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model HYUNDAI - DP180LB
Alternator Made and Model Aksa - AK 6540 
Control Panel Model DSE 7320 
Canopy MS 80 TRP
 
3 Phase, 50 Hz, PF 0.8
VOLTAGESTANDBY RATING (ESP) (ESP)PRIME RATING (PRP) (PRP)
kVAkWkVAkWAmp
400/231 710 568.0 640 512.0 1024.83
STANDBY RATING (ESP) (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

PRIME RATING (PRP) (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
Engine Specifications
Engine HYUNDAI
Engine Model DP180LB
NO. OF CYLINDERS AND BUILD 10 cylinders - V type
BORE AND STROKEmm 128 X 142
TOTAL DISPLACEMENTL 18.273
Aspiration Turbo Charged and Intercooled (Air to Air)
COMPRESSION RATIO 15.0:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 34
Standby Power (kW/HP) 612/832 kW
Prime Power (kW/HP) 556/756 kW
Block Heater QTY
  1
Block Heater Power (Watt)
  3000
Fuel Type
  Diesel
Injection Type and System
  Direct
Type of Fuel Pump
  Bosh In-Line P Type
Governor System
  Electronic
Operating Voltage (Vdc)
  24 Vdc
Battery and Capacity (Qty/Ah)
  2x120
Charge Alternator (A)
  45
Cooling Method
  Water Cooled
Cooling Fan Air Flow (m3/min)
  700
Coolant Capacity (engine only / with radiator) (lt)
  21/112.2
Air Filter
  Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
  136.4
Fuel Cons. Prime With %75 Load (lt/hr)
  103.8
Fuel Cons. Prime With %50 Load (lt/hr)
  71.2
 
Alternator Specifications
Manufacturer Aksa
Alternator Made and Model AK 6540
Frequency (Hz)Hz 50
Power (kVA)kVA 675
DESIGN   Brushless
VOLTAGEV 400
Phase 3
A.V.R. SX440
Voltage Regulation(+/-) 1%
Insulation System H
Protection IP22
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 62.1
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
4000 3205 1550 2056 850
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
MS 80 TRP
4940 4810 1610 2620 850
Standart Specifications

Water cooled, Diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately(for open sets) 
Static battery charger 
Manual for application and installation

Optional Equpiments

ENGINE
• Fuel-Water Seperator Filter
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• PMG excitation + AVR
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Transition synchronization with mains
• Remote annunciator panel
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three Pole Contactor
• Four Pole Contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Electrical oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• Automatic transfer switch