Disel generator
Aksa AJD 132

Model : AJD 132
Product : JOHN DEERE
CONTROL SYSTEM : DSE 6020
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AJD 132
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model JOHN DEERE - 6068TF220
Alternator Made and Model Mecc Alte - ECP 34-1L/4 A 
Control Panel Model DSE 6020 
Canopy AK 49
3 Phase, 50 Hz, PF 0.8
VOLTAGESTANDBY RATING (ESP) (ESP)PRIME RATING (PRP) (PRP)
kVAkWkVAkWAmp
400/231 132 105.6 120 96.0 190.53
STANDBY RATING (ESP) (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

PRIME RATING (PRP) (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
Engine Specifications
Engine JOHN DEERE
Engine Model 6068TF220
NO. OF CYLINDERS AND BUILD 6 cylinders - in line
BORE AND STROKEmm 106 X 127
TOTAL DISPLACEMENTL 6.8
Aspiration Turbo Charged
COMPRESSION RATIO 17.0:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 17
Standby Power (kW/HP) 121/162 kW
Prime Power (kW/HP) 109/146 kW
Block Heater QTY
  1
Block Heater Power (Watt)
  1500
Fuel Type
  Diesel
Injection Type and System
  Direct
Type of Fuel Pump
  Stanadyne DB4 Rotary Type
Governor System
  Mechanic
Operating Voltage (Vdc)
  12 Vdc
Battery and Capacity (Qty/Ah)
  1x85
Cooling Method
  Water Cooled
Coolant Capacity (engine only / with radiator) (lt)
  11.3/35
Air Filter
  Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
  26.7
Fuel Cons. Prime With %75 Load (lt/hr)
  20.2
Fuel Cons. Prime With %50 Load (lt/hr)
  14
Alternator Specifications
Manufacturer Mecc Alte
Alternator Made and Model ECP 34-1L/4 A
Frequency (Hz)Hz 50
Power (kVA)kVA 135
DESIGN   4 Pole,  Brushless
VOLTAGEV 400
Phase 3
A.V.R. DSR
Voltage Regulation(+/-) 1
Insulation System H
Protection IP23
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 19.3
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
  2300 1080 1618 340
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
AK 49
  3402 1147 2032 340
Standart Specifications

ENGINE
• Electronic governor control
• Fuel-Water Seperator Filter
• Low water level alarm
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• Main line circuit breaker
CONTROL SYSTEM
• Remote annunciator panel
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Double wall chassis
• Supplied with oil and coolant - 30 °C
• Battery isolating switch

Optional Equpiments

ENGINE
• Electronic governor control
• Fuel-Water Seperator Filter
• Low water level alarm
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• Main line circuit breaker
CONTROL SYSTEM
• Remote annunciator panel
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Double wall chassis
• Supplied with oil and coolant - 30 °C
• Battery isolating switch

Download
Get FREE expert advice in 15 minutes
Special offers