Disel generator
Aksa APD 1650 M

Model : APD 1650 M
Product : MITSUBISHI
CONTROL SYSTEM : DSE 7320
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name APD 1650 M
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model MITSUBISHI - S12R-PTAA2
Alternator Made and Model Mecc Alte - ECO 46-1S/4 A 
Control Panel Model DSE 7320 
Canopy AK 99 - External Removable Silencer
3 Phase, 50 Hz, PF 0.8
VOLTAGESTANDBY RATING (ESP) (ESP)PRIME RATING (PRP) (PRP)
kVAkWkVAkWAmp
400/231 1650 1320.0 1500 1200.0 2381.64
STANDBY RATING (ESP) (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

PRIME RATING (PRP) (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
Engine Specifications
Engine MITSUBISHI
Engine Model S12R-PTAA2
NO. OF CYLINDERS AND BUILD 12 cylinders - V type
BORE AND STROKEmm 170 X 180
TOTAL DISPLACEMENTL 49.03
Aspiration Turbo Charged and After Cooled
COMPRESSION RATIO 13.5:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 180
Standby Power (kW/HP) 1441/1932 kW
Prime Power (kW/HP) 1314/1761 kW
Block Heater QTY
  2
Block Heater Power (Watt)
  3000
Fuel Type
  Diesel
Injection Type and System
  Direct
Type of Fuel Pump
  Mitsubishi PS6x2 (In-Line)
Governor System
  Electronic
Operating Voltage (Vdc)
  24 Vdc
Battery and Capacity (Qty/Ah)
  4x143
Charge Alternator (A)
  30
Cooling Method
  Water Cooled
Cooling Fan Air Flow (m3/min)
  1800
Coolant Capacity (engine only / with radiator) (lt)
  33/317
Air Filter
  Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
  308
Fuel Cons. Prime With %75 Load (lt/hr)
  234.2
Fuel Cons. Prime With %50 Load (lt/hr)
  163.3
Alternator Specifications
Manufacturer Mecc Alte
Alternator Made and Model ECO 46-1S/4 A
Frequency (Hz)Hz 50
Power (kVA)kVA 1500
DESIGN   Brushless
VOLTAGEV 400
Phase 3
A.V.R. DER1
Voltage Regulation(+/-) 0.5
Insulation System H
Protection IP23
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 135
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
11400 4980 2190 3080 2000
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
AK 99 - External Removable Silencer
15450 9000 2800 3300 2200
Standart Specifications

Water cooled diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Steel base frame and anti-vibration isolators 
Spare external fuel tank (open set) 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately 
Static battery charger 
Manual for application and installation 
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 
Generators Sets’ can take 100% load at one step according to NFPA110 

Optional Equpiments

ENGINE
• Fuel-Water Seperator Filter
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Paralel system with mains.
• Transition synchronization with mains
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Supplied with oil and coolant - 30 °C

Download
Get FREE expert advice in 15 minutes