Almaty
+7 771 781 00 60, +7 727 224 31 11
Сервис и зап.части +7 771 780 46 42
Astana
+7 771 780 46 48
info@akgen.kz


Language selection:

Disel generator
Aksa AVP 275

Model : AVP 275
Product : VOLVO PENTA
CONTROL SYSTEM : DSE 7320
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AVP 275 
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model VOLVO - TAD734GE
Alternator Made and Model Mecc Alte - ECO 38-1L/4 A 
Control Panel Model DSE 7320 
Canopy MS 60
3 Количество фаз, 50 Hz, PF 0.8
Напряжение (В)Мощность Standby (ESP)Мощность Prime (PRP)
kVAkWkVAkWAmp
400/231 275 220.0 250 200.0 396.94
Мощность Standby (ESP) : Используется при подаче электроэнергии переменной электрической нагрузке в случае прерывания надежного источники сети. ESP совместим с ISO8528. Перегрузка не допускается.

Мощность Prime (PRP) : Используется для неограниченных рабочих часов ежегодно при подаче электроэнергии переменной электрической нагрузке. PRP совместим с ISO 8528. Согласно ISO3046 в 12-часовой период работы 1 час используется для 10% перегрузки.
Engine Specifications
Engine VOLVO
Engine Model TAD734GE
NO. OF CYLINDERS AND BUILD 6 cylinders - in line
BORE AND STROKEmm 108 X 130
TOTAL DISPLACEMENTL 7.15
Aspiration Turbo Charged and After Cooled
COMPRESSION RATIO 17.0:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 29
Standby Power (kW/HP) 250/340 kW
Prime Power (kW/HP) 227/309 kW
Block Heater QTY
  1
Block Heater Power (Watt)
  1500
Fuel Type
  Diesel
Injection Type and System
  Direct
Type of Fuel Pump
  HPCR (High Pressure Common Rail)
Governor System
  ECM
Operating Voltage (Vdc)
  24 Vdc
Battery and Capacity (Qty/Ah)
  2x85
Charge Alternator (A)
  100
Cooling Method
  Water Cooled
Cooling Fan Air Flow (m3/min)
  312
Coolant Capacity (engine only / with radiator) (lt)
  10/32
Air Filter
  Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
  54.5
Fuel Cons. Prime With %75 Load (lt/hr)
  43.5
Fuel Cons. Prime With %50 Load (lt/hr)
  31.1
Alternator Specifications
Manufacturer Mecc Alte
Alternator Made and Model ECO 38-1L/4 A
Frequency (Hz)Hz 50
Power (kVA)kVA 250
DESIGN   4 Pole,  Brushless
VOLTAGEV 400
Phase 3
A.V.R. DSR
Voltage Regulation(+/-) 1
Insulation System H
Protection IP23
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 32
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
2355 2750 1300 1777 470
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
MS 60
2885 3960 1356 2167 470
Standart Specifications

Water cooled, Diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately(for open sets) 
Static battery charger 
Manual for application and installation 
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 
Generators Sets’ can take 100% load at one step according to NFPA110

Optional Equpiments

ENGINE
• Fuel-Water Seperator Filter
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• PMG excitation + AVR
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Paralel system with mains.
• Transition synchronization with mains
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Electrical oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Supplied with oil and coolant - 30 °C

Download
Get FREE expert advice in 15 minutes
Special offers