Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies (8 – 275kVA) fit directly to the open generator set to provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
- TS ISO 8528
- TS ISO 9001-2008
- CE - SZUTEST
- 2000/14/EC
VOLTAGE(V) | Standby (ESP) | Prime (PRP) | Standby Aмпер | ||
kVa | kW | kVa | kW | ||
400/231 | 71,20 | 89,00 | 62,40 | 78,00 | 129,26 |
Standby (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source.ESP is in accordance with ISO 8528. Overload is not allowed.
Prime (PRP) Applicable for supplying power to varying electical load for unlimited hours. PRP is in accordance with ISO 8528. 10% overload capability is available for a period of 1 hour within 12-hour period of operation, in accordance with ISO 3046.
Microprocessor controlled - 132x64 pixel LCD display makes information easy to read
- Front panel programming and also via PC software
- Soft touch membrane keypad and five key menu navigation
- Remote communications via USB, RS485 MODBUS
- Event logging (50) showing date and time
- Multiple date and time engine exercise mode and maintenance scheduler
- Engine block heater control
- Controls; stop, start, manuel, auto, mute lamb test/transfer to generator, transfer to mains, menu navigation.
ENGINE
External radiator
Filter for separating water fraction from fuel
Heating oil
ALTERNATOR
Anti-condensation heater
Output circuit breaker
CONTROL SYSTEM
Automatic synchronization and power control system
Parallel system with external network
Synchronization system between the network
Remote Alarm Panel
Emergency engine stop
Remote control via modem
Ground connection point
Ammeter current
Load transfer panel
Three or four poles contactor
Three or four pole motor running switch
Other accessories
Charging current control
Automatic fuel pumping system
Manual oil drain pump
Fuel level sensors
Muffler
Enclosure: Protection against precipitation and noise reduction
Air duct adapter (in front of the radiator)
Supply and exhaust shutters with an electric drive
Noise suppression air chamber
Those. Kit (for maintenance)
Maintenance kit (1500/3000 hours)
Antifreeze and engine lubricating oil (when operating at - 30C)